Home > DRAPER > DRAPER PT1202VSF 1200W 230V Variable Speed Router Instruction Manual

DRAPER PT1202VSF 1200W 230V Variable Speed Router Instruction Manual

10. TROUBLESHOOTING  
NOTE: Remove the plug from the socket before carrying out adjustment, servicing or  
maintenance.  
PROBLEM  
POSSIBLE CAUSE  
REMEDY  
Motor  
does not start  
1. Fuse  
1. Replace/reset time delay  
fuse or circuit breaker  
2. Brushes worn  
3. Other  
2. Have brushes replaced by  
authorised service agent  
3. Return to authorised  
service agent  
Machine vibrates  
1. Router bit not suitable  
for application  
1. Seek guidance on bit  
selection  
2. Router bit blunt  
2. Stop machine. When  
stopped, replace with a  
sharp bit  
3. Change direction of  
travel  
3. Incorrect direction of  
travel  
Bit will not cut  
1. Attempting to remove  
excess material  
1. Reduce plunge depth  
2. Router bit blunt  
2. Stop machine. When  
stopped, replace with a  
sharp bit  
3. Change direction of travel  
3. Incorrect direction of  
travel  
16  
GeneralDetails
NameDRAPER PT1202VSF 1200W 230V Variable Speed Router Instruction Manual
MakeDRAPER
LanguageEnglish
FiletypePDF (Download)
File size0.24 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

If you have any questions regarding DRAPER PT1202VSF 1200W 230V Variable Speed Router Instruction Manual, please ask here and describe the problem in detail.

Leave a Reply

Your email address will not be published. Required fields are marked *

8 + 16 =