I/O connection, Relay output
Maximum voltage/current
Connect resistance
Isolation
220 VDC/2A
<100mΩ
To all other ports
Connector
Detachable latch terminal
Conductor cross section
Stripping length cable
Number of ports
0.14 - 1.5 mm² (AWG 28 - 16)
7 mm
2
I/O connection, Digital input
Maximum voltage/current
Voltage levels
24 VDC
Logic one: >9.9 VDC
Logic zero: <7.4 VDC
Isolation
To all other ports
Connector
Detachable latch terminal
Conductor cross section
Stripping length cable
Number of inputs
0.14 - 1.5 mm² (AWG 28 - 16)
7 mm
6
Console port
Electrical specification
Data rate
USB 2.0 host interface
115.2 kbit/s
Circuit type
SELV
Data format
8 data bits, no parity, 1 stop bit, no flow control
USB receptacle connector type C
Connection
18