CNCU FC300 Easy Route CNC Router Instructions
BEST FC300 Inverter Setngs and Wirings for EasyRoute CNC Router
htps://am.co.za/
P087 = 101
Set this value to reset Inverter Parameter to Factory Default, all below
setngs are based on default
(Reboot aſter Reset, then change:)
P017 = 0.5
P018 = 5
P038 = 4
P039= 5
Stop Breaking Time, 0.5 seconds
DC Breaking Voltage, 5%
Acceleraton Time, 4 seconds
Deceleraton Time, 5 seconds
(Those should be on default, unless you want to change each gear frequency)
P021 = 400
P030 = 0
Maximum frequency for our spindles is 400MHz
Multispeed frequency 0
Multispeed frequency 1
Multispeed frequency 2
Multispeed frequency 3
Multispeed frequency 4
Multispeed frequency 5
Multispeed frequency 6
Multispeed frequency 7
SOFF
P031 = 100
P032 = 150
P033 = 200
P034 = 250
P035 = 300
P036 = 350
P037 = 400
S1
S2
S3
S4
S5
S6
S7 Speed on Panel
Reboot One More Time Aſter All Parameters Changed.
BEST FC300 Manual on CNCU.CO.ZA
Page 18, secton “3. 4. Parameter modificaton method” explained how to change above values.
Wiring:
You may need to connect GND to PE/COM if its not ground already.