Home > Hercules > HERCULES HE042 Compact Trim Router Owner’s Manual

HERCULES HE042 Compact Trim Router Owner’s Manual

Extension Cords  
Warning Symbols and Definitions  
1. Grounded tools require a three wire extension cord.  
Double Insulated tools can use either  
This is the safety alert symbol. It is used to  
alert you to potential personal injury hazards.  
Obey all safety messages that follow this symbol to  
avoid possible injury or death.  
a two or three wire extension cord.  
2. As the distance from the supply outlet increases,  
you must use a heavier gauge extension cord.  
Using extension cords with inadequately sized wire  
causes a serious drop in voltage, resulting in loss of  
power and possible tool damage. (See Table A.)  
Indicates a hazardous  
situation which, if not  
avoided, will result in death or serious injury.  
Indicates a hazardous  
situation which, if not  
avoided, could result in death or serious injury.  
3. The smaller the gauge number of the wire, the  
greater the capacity of the cord. For example,  
a 14 gauge cord can carry a higher current  
than a 16 gauge cord. (See Table A.)  
Indicates a hazardous  
situation which, if not  
avoided, could result in minor or moderate injury.  
4. When using more than one extension cord to make  
up the total length, make sure each cord contains at  
least the minimum wire size required. (See Table A.)  
Addresses practices not  
related to personal injury.  
5. If you are using one extension cord for more  
than one tool, add the nameplate amperes  
and use the sum to determine the required  
minimum cord size. (See Table A.)  
Symbology  
6. If you are using an extension cord outdoors, make  
sure it is marked with the suffix “W-A” (“W” in  
Double Insulated  
Canada) to indicate it is acceptable for outdoor use.  
7. Make sure the extension cord is properly wired  
and in good electrical condition. Always replace  
a damaged extension cord or have it repaired  
by a qualified electrician before using it.  
Volts  
V
~
A
Alternating Current  
8. Protect the extension cords from sharp objects,  
excessive heat, and damp or wet areas.  
Amperes  
TAbLE A: RECOMMENDED MINIMUM WIRE  
GAUGE FOR EXTENSION CORDS* (120/240 VOLT)  
No Load Revolutions per Minute (RPM)  
n xxxx/min.  
0
EXTENSION CORD  
LENGTH  
NAMEPLATE  
WARNING marking concerning Risk  
of Eye Injury. Wear ANSI-approved  
safety goggles with side shields.  
AMPERES  
(at full load)  
25´ 50´ 75´ 100´ 150´  
0 – 2.0  
2.1 – 3.4  
18  
18  
18  
18  
18  
14  
12  
18  
18  
18  
16  
14  
12  
10  
18  
18  
16  
14  
12  
10  
-
18  
16  
14  
12  
10  
-
16  
14  
12  
12  
-
Read the manual before  
set-up and/or use.  
3.5 – 5.0  
WARNING marking  
5.1 – 7.0  
concerning Risk of Fire.  
Do not cover ventilation ducts.  
Keep flammable objects away.  
WARNING marking concerning  
Risk of Electric Shock.  
7.1 – 12.0  
12.1 – 16.0  
16.1 – 20.0  
-
-
-
* based on limiting the line voltage drop to five volts at  
Properly connect power cord  
to appropriate outlet.  
150% of the rated amperes.  
SPECIFICATIONS  
Electrical Rating  
No Load Speed  
Collet Size  
120ꢀVAC / 60ꢀHz / 7ꢀA  
n : 15,000ꢀ - 32,000/min  
0
1/4"  
Max Plunge Depth  
1-1/2"  
Item 59436  
For technical questions, please call 1-888-866-5797.  
Page 5  
GeneralDetails
NameHERCULES HE042 Compact Trim Router Owner’s Manual
MakeHercules
LanguageEnglish
FiletypePDF (Download)
File size MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

If you have any questions regarding HERCULES HE042 Compact Trim Router Owner’s Manual, please ask here and describe the problem in detail.

Leave a Reply

Your email address will not be published. Required fields are marked *

11 + nine =

HERCULES HCB043 20V Brushless Compact Router Owner’s Manual
HERCULES HCB043 20V Brushless Compact Router Owner’s Manual
HERCULES HE041 Variable Speed Fixed Base Router with Plunge Base Kit Owner’s Manual
HERCULES HE041 Variable Speed Fixed Base Router with Plunge Base Kit Owner’s Manual

HERCULES HE042 Compact Trim Router Owner’s Manual