HERCULES HE042 Compact Trim Router Owner’s Manual
Extension Cords
Warning Symbols and Definitions
1. Grounded tools require a three wire extension cord.
Double Insulated tools can use either
This is the safety alert symbol. It is used to
alert you to potential personal injury hazards.
Obey all safety messages that follow this symbol to
avoid possible injury or death.
a two or three wire extension cord.
2. As the distance from the supply outlet increases,
you must use a heavier gauge extension cord.
Using extension cords with inadequately sized wire
causes a serious drop in voltage, resulting in loss of
power and possible tool damage. (See Table A.)
Indicates a hazardous
situation which, if not
avoided, will result in death or serious injury.
Indicates a hazardous
situation which, if not
avoided, could result in death or serious injury.
3. The smaller the gauge number of the wire, the
greater the capacity of the cord. For example,
a 14 gauge cord can carry a higher current
than a 16 gauge cord. (See Table A.)
Indicates a hazardous
situation which, if not
avoided, could result in minor or moderate injury.
4. When using more than one extension cord to make
up the total length, make sure each cord contains at
least the minimum wire size required. (See Table A.)
Addresses practices not
related to personal injury.
5. If you are using one extension cord for more
than one tool, add the nameplate amperes
and use the sum to determine the required
minimum cord size. (See Table A.)
Symbology
6. If you are using an extension cord outdoors, make
sure it is marked with the suffix “W-A” (“W” in
Double Insulated
Canada) to indicate it is acceptable for outdoor use.
7. Make sure the extension cord is properly wired
and in good electrical condition. Always replace
a damaged extension cord or have it repaired
by a qualified electrician before using it.
Volts
V
~
A
Alternating Current
8. Protect the extension cords from sharp objects,
excessive heat, and damp or wet areas.
Amperes
TAbLE A: RECOMMENDED MINIMUM WIRE
GAUGE FOR EXTENSION CORDS* (120/240 VOLT)
No Load Revolutions per Minute (RPM)
n xxxx/min.
0
EXTENSION CORD
LENGTH
NAMEPLATE
WARNING marking concerning Risk
of Eye Injury. Wear ANSI-approved
safety goggles with side shields.
AMPERES
(at full load)
25´ 50´ 75´ 100´ 150´
0 – 2.0
2.1 – 3.4
18
18
18
18
18
14
12
18
18
18
16
14
12
10
18
18
16
14
12
10
-
18
16
14
12
10
-
16
14
12
12
-
Read the manual before
set-up and/or use.
3.5 – 5.0
WARNING marking
5.1 – 7.0
concerning Risk of Fire.
Do not cover ventilation ducts.
Keep flammable objects away.
WARNING marking concerning
Risk of Electric Shock.
7.1 – 12.0
12.1 – 16.0
16.1 – 20.0
-
-
-
* based on limiting the line voltage drop to five volts at
Properly connect power cord
to appropriate outlet.
150% of the rated amperes.
SPECIFICATIONS
Electrical Rating
No Load Speed
Collet Size
120ꢀVAC / 60ꢀHz / 7ꢀA
n : 15,000ꢀ - 32,000/min
0
1/4"
Max Plunge Depth
1-1/2"
Item 59436
For technical questions, please call 1-888-866-5797.
Page 5
| General | Details |
|---|---|
| Name | HERCULES HE042 Compact Trim Router Owner’s Manual |
| Make | Hercules |
| Language | English |
| Filetype | PDF (Download) |
| File size | MB |
If you have any questions regarding HERCULES HE042 Compact Trim Router Owner’s Manual, please ask here and describe the problem in detail.

HERCULES HCB043 20V Brushless Compact Router Owner’s Manual

HERCULES HE041 Variable Speed Fixed Base Router with Plunge Base Kit Owner’s Manual