Troubleshooting  
Problem  
Tool will  
not start.  
Possible Causes  
1. Cord not connected.  
Likely Solutions  
1. Check that cord is plugged in.  
2. No power at outlet.  
2. Check power at outlet. If outlet is unpowered,  
turn off tool and check circuit breaker.  
If breaker is tripped, make sure circuit is right  
capacity for tool and circuit has no other loads.  
3. Tool’s thermal reset breaker  
tripped (if equipped).  
3. Turn off tool and allow to cool.  
Press reset button on tool.  
4. Internal damage or wear.  
(Carbon brushes or  
4. Have qualified technician service tool.  
Power Switch, for example.)  
1. Forcing tool to work too fast.  
Tool operates  
slowly.  
1. Allow tool to work at its own rate.  
2. Extension cord too long or  
cord diameter too small.  
2. Eliminate use of extension cord. If an extension cord  
is needed, use one with the proper diameter for its  
length and load. See Extension Cords on page 4.  
1. Have qualified technician replace brushes.  
Performance  
decreases  
over time.  
1. Carbon brushes worn  
or damaged.  
2. Cutting bit dull or damaged.  
2. Use sharp bits. Replace as needed.  
Have qualified technician service tool.  
Excessive noise Internal damage or wear. (Carbon  
or rattling.  
brushes or bearings, for example.)  
1. Forcing tool to work too fast.  
2. Cutting bit dull or damaged.  
3. Blocked motor housing vents.  
Overheating.  
1. Allow tool to work at its own rate.  
2. Use sharp bits. Replace as needed.  
3. Wear ANSI-approved safety goggles and  
NIOSH-approved dust mask/respirator while  
blowing dust out of motor using compressed air.  
4. Motor being strained by long or  
small diameter extension cord  
4. Eliminate use of extension cord. If an extension cord  
is needed, use one with the proper diameter for its  
length and load. See Extension Cords on page 4.  
Follow all safety precautions whenever diagnosing or servicing the tool.  
Disconnect power supply before service.  
Item 57368  
For technical questions, please call 1-888-866-5797.  
Page 13  
GeneralDetails
NameHERCULES HE041 Variable Speed Fixed Base Router with Plunge Base Kit Owner’s Manual
MakeHercules
LanguageEnglish
FiletypePDF (Download)
File size MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

If you have any questions regarding HERCULES HE041 Variable Speed Fixed Base Router with Plunge Base Kit Owner’s Manual, please ask here and describe the problem in detail.

Leave a Reply

Your email address will not be published. Required fields are marked *

8 + 10 =

HERCULES HCB043 20V Brushless Compact Router Owner’s Manual
HERCULES HCB043 20V Brushless Compact Router Owner’s Manual
HERCULES HE042 Compact Trim Router Owner’s Manual
HERCULES HE042 Compact Trim Router Owner’s Manual

HERCULES HE041 Variable Speed Fixed Base Router with Plunge Base Kit Owner’s Manual