Ibex-RT-630-5G Series EN 50155 5G and WLAN Router User Manual
Environmental
phenomena
Basic
standard
Description
Test levels
Temperatures
EN 60068-2-1
EN 60068-2-2
EN 60068-2-14
Operational
-40 to +70°C (-40 to +158°F)a.
-55 to +85°C (-67 to +185°F)
Storage and
transport
Humidity
EN 60068-2-30 Operational
5-95 % relative humidity
Storage and
transport
Altitude
MTBF
Operational
IEC TR 62380
2000 m
283'858 hours
Vibration
EN 60068-2-64 Operational,
2.3 m/s2 random, 5 to 2000 Hz, 3 x 4 h
(random)
EN 60068-2-64 Operational,
(random) endurance test
endurance test
11.44 m/s2 random, 5 to 150 Hz, 3 x 5 h
Shockb.
Weight
EN 60068-2-27 Operational
100 m/s2, 30 ms, 3 x 6 shocks (half sine)
10 g, 11 ms, 3 x 6 shocks (saw tooth)
MIL STD 810,
M516.7
1650 gr
IP66c.
Degree of protection EN 60529
Cooling
Enclosure
Convection
PD2
Pollution degree
EN 61010-1
IPC-A-610
Conformal coating
type
Electronic
modules
AR (Acrylic)
a.Refer to "Safety and Regulations" chapter regarding touch temperature
b.The power and Ethernet cables need to be fastened 200 mm or closer to the unit. The same recommendation
applies to the Antenna cables.
c.Provided all connectors are connected with IP66 cabling or fitted with protective caps (delivered with the unit)
and tightened to the specified torque
Table 11. Environmental and mechanical conditions