The R232 ships with a right-angle IEC power cable similar to  
the one shown on the right.  
The plug is inserted in the AC receptacle on in the Pocket  
Power Supply opening and the wire is routed along the cable  
management tray as shown in Figure 5.  
Figure 5: R232 side view with AC power cord installed and properly configured.  
2.1.2 R232-48VDC Power Connections - DC  
The model R232-48VDC uses a different connector in the Pocket Power Supply  
opening. This connector is a two-pin removeable terminal block where one side  
remains mounted to the chassis as shown in Figure 6, while the mating connector  
can be easily removed to facilitate installation of the power cabling.  
IMPORTANT NOTE:  
CLOSELY OBSERVE THE CONNECTION POLARITY TO AVOID DAMAGE!  
Figure 6: R232-48VDC Pocket Power Supply with removeable terminal receptacle for DC input  
(shown with mating connector removed)  
Along the same side of the chassis is the power cable management tray which  
allows the power cable to be cleanly supported toward the rear of the chassis.  
The R232-48VDC is not supplied with any power wiring. This is the sole  
responsibility of the customer. The terminal strip can accept wires up to 16 gauge.  
R232 / R232-48VDC Installation Guide  
Page 5 of 8  
GeneralDetails
NameDigital Alert Systems R232 Multi Port RF Router Installation Guide
MakeDigital Alert Systems
LanguageEnglish
FiletypePDF (Download)
File size0.36 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

If you have any questions regarding Digital Alert Systems R232 Multi Port RF Router Installation Guide, please ask here and describe the problem in detail.

Leave a Reply

Your email address will not be published. Required fields are marked *

sixteen − 15 =

Digital Alert Systems R232 Multi Port RF Router Installation Guide