C
Digital Output & Digital Inputs  
Fig. 10  
Current scheme of the main connector  
Characteristic  
Value  
Type of digital output 2  
Open drain MOSFET  
200 mA  
Maximum current (ext,source)  
Isolation (both DI & DO)  
DI voltage range  
1.5 kV  
0 to 24 VDC  
DI protection  
33 VDC Max  
0 to 5 VDC  
DI OFF state — input voltage range  
DI ON state — input voltage range  
DI ON state — current range  
10 to 30 VDC  
From 3,8 mA @ 12 VDC to 8,2 mA @ 24 VDC  
The Digital Output is activated by an open drain MOSFET transistor driven by an optocoupler. The  
maximum current flow inside this transistor has a value above the one specified in the Cosy+, in  
order to cope with the switching power losses.  
The transistor used is in an open drain type with predrive. This means the relay power supply has  
to be supplied from an external source to the predrive electronics.  
The diagram below shows the external wiring needed for proper operation of the digital output.  
A relay has been chosen for this sample application but any load within the specifications can be  
used instead.  
This is a sink only output to ground (the transistor acts as a switch ground).  
2. During the starting boot process, the DO will be switched ON for a short time (2 seconds)  
IG-0031-00 1.1 en-US  
Ewon Cosy+ Installation Guide  
 
GeneralDetails
NameEWON EC71330 Cosy 131 Ethernet router Installation Guide
MakeEWON
LanguageEnglish
FiletypePDF (Download)
File size0.42 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

If you have any questions regarding EWON EC71330 Cosy 131 Ethernet router Installation Guide, please ask here and describe the problem in detail.

Leave a Reply

Your email address will not be published. Required fields are marked *

four × 2 =

EWON EC71330 Cosy 131 Ethernet router Installation Guide