UfiSpace S9600-64X 100G Aggregation Router Installation Guide

Installation Location Statement  
It is recommended that the device be installed only in a server room or computer  
room where access is:  
Restricted to qualified service personnel or users familiar with restrictions  
applied to the location, reasons therefore, and any precautions required.  
Only afforded by the use of a tool or lock and key, or other means of security,  
and controlled by the authority responsible for the location.  
Suitable for installation in Information Technology Rooms in accordance with Article  
645 of the National Electrical Code and NFPA 75.  
Cautions and regulatory compliance statements for NEBS:  
“Suitable for installation as part of the Common Bonding Network (CBN)”  
“An external Surge Protection Device (SPD) must be used with AC powered equipment  
and that the Surge Protection Device is to be installed at the AC power service entrance.”  
“System can be installed in Network Telecommunications Facilities where the National  
Electric Code applies”  
The approximate system boot time when the AC (or DC) power source is connected is  
100 secs in Ubuntu Linux system. (The boot up time may be different depending on  
different NOS vendors)  
The approximate link time for the OOB Ethernet port when reconnected is 40 secs base  
on Ubuntu Linux system (The link time may be different depending on different NOS  
vendors)  
The design of the equipment is that the RTN terminal should be isolated from the chassis  
or rack. (The DC input terminals is DCI (Isolated DC return))  
“WARNING: The intrabuilding port OOB (Ethernet) of the equipment or subassembly is  
suitable for connection to intrabuilding or unexposed wiring or cabling only. The intra‐  
building port(s) of the equipment or subassembly MUST NOT be metallically connected  
to interfaces that connect to the OSP or its wiring for more than 6 meters (approximately  
20 feet). These interfaces are designed for use as intrabuilding interfaces only (Type 2, 4,  
or 4a ports as described in GR1089) and require isolation from the exposed OSP cabling.  
The addition of Primary Protectors is not sufficient protection in order to connect these  
interfaces metallically to an OSP wiring system.”  
S960064X Hardware Installation Guide | 33  
GeneralDetails
NameUfiSpace S9600-64X 100G Aggregation Router Installation Guide
MakeUfiSpace
LanguageEnglish
FiletypePDF (Download)
File size0.8 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

If you have any questions regarding UfiSpace S9600-64X 100G Aggregation Router Installation Guide, please ask here and describe the problem in detail.

Leave a Reply

Your email address will not be published. Required fields are marked *

nine + 2 =

UfiSpace S9500-30XS Gateway Router Installation Guide
UfiSpace S9500-30XS Gateway Router Installation Guide
ufiSpace S9600-72XC Router Installation Guide
ufiSpace S9600-72XC Router Installation Guide
UfiSpace S9600-32X 100G Aggregation Router Installation Guide
UfiSpace S9600-32X 100G Aggregation Router Installation Guide
UfiSpace S9501-28SMT Gateway Router Installation Guide
UfiSpace S9501-28SMT Gateway Router Installation Guide

UfiSpace S9600-64X 100G Aggregation Router Installation Guide