4.6 Parameters of I/O Ports
Electrical characteristics of the binary inputs are in Table 13. Status of the binary input is
reported in the GUI on General Status page or can be retrieved in the Shell via io get bin0
command.
get command output
Voltage
Web interface status
0
1
≤ 0.8 V (0.5 mA))
≥ 2 V
On
Off
Table 13: Electrical Characteristics of Binary Inputs
The maximum binary output load is 100 mA at 9 – 48 V.
4.7 System Configuration
The main parametes of the system are listed in Table 14.
Other technical parameters
CPU architecture
CPU frequency
CPU power
ARM926EJ-S
600 MHz
4,72 DMIPS/MHz
Flash memory
64 MB NOR Flash
• 12 MB for Router Apps
• 2 MB for customer data
RAM size
Watchdog
RTC
128 MB
HW Watchdog
Battery Backup RTC
Table 14: System Configuration
28