ADVANTECH SL302 SmartStart LTE Router User Manual
SmartStart SL302
Binary Input
Logical 0 / 1∗
logic 0
Voltage
Web interface status
0 – 0.7 V
1.6 – 36 V
On
Off
logic 1
Table 7: Characteristics of binary input
∗
The binary input status in the Shell is returned via io get bin0.
Binary Output
The binary output is open in the default configuration. The current of the binary output is
limited by a resettable fuse (200 mA).
Binary inputs and output connections
Binary inputs and output connections example:
Figure 18: Binary connection
Low Power Mode
The router can be put into low power mode using a special command lpm. It can then be
awakened by an activity on binary input or using an internal timer. For more details of this
command, see the application note Commands and Scripts [3]. Consumption in LPM mode
may vary depending on the configuration of the router.
All metal parts are connected together with the negative pole of power supply (common pole).
However, the router box may not be connected to the negative pole properly.
19
| General | Details |
|---|---|
| Name | ADVANTECH SL302 SmartStart LTE Router User Manual |
| Make | Advantech |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.46 MB |
If you have any questions regarding ADVANTECH SL302 SmartStart LTE Router User Manual, please ask here and describe the problem in detail.

ADVANTECH ICR-3200 Cellular Router Instruction Manual

ADVANTECH ICR-2701 Engineering Portal Cellular Router User Guide

ADVANTECH ICR-2531 LTE Router User Manual

advantech ICR-3831 RAILWAY 4G LTE ROUTER & GATEWAY User Guide

ADVANTECH ICR-2431 LTE Router User Manual

ADVANTECH ICR-2041 LTE Router User Manual