Installation and Startup  
Low Side Current Sink Output  
You can use Pin 4 as a low side current sink; for example, to drive a relay.  
LX40  
Vin  
Vin  
Internal pull-up  
resistor  
Off  
Protection  
Circuitry  
External solenoid/relay circuit  
ISink = 500 mA (Typ)*  
Pin 4 (power connector)  
* See Table 2-7 on page 29 for more details.  
Figure 2-17: Low Side Current Sink  
Table 2-7: Low Side Current Sink  
Pull-up  
Off  
State  
On  
Minimum Typical Maximum  
Comments  
300 mA  
500 mA  
0 mA  
850 mA  
I_Typical = 25°C  
I_Min = 65°C  
I_Max = -30°C  
Off  
Off  
V
= 12  
in  
Note: The router protection circuitry has a high-impedance (~200 kΩ) path to ground. If Pin 4 is  
connected to 12 V, there will be a small current flow (~100 μA) into Pin 4 during bootup. This flow is  
countered when the internal pull-up resistor (10 kΩ) becomes active after bootup. Depending on  
your application, you may need to install an external pull-up resistor (10 kΩ) in order to nullify the  
small input current flow for the first 30 seconds during bootup.  
Rev. 4 January 2022  
29  
41112510  
GeneralDetails
NameSIERRA WIRELESS AirLink LX40 Enterprise LTE Router User Guide
MakeSIERRA WIRELESS
LanguageEnglish
FiletypePDF (Download)
File size0.96 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

If you have any questions regarding SIERRA WIRELESS AirLink LX40 Enterprise LTE Router User Guide, please ask here and describe the problem in detail.

Leave a Reply

Your email address will not be published. Required fields are marked *

17 − 13 =

SIERRA WIRELESS XR80 5G Cellular Router Instructions
SIERRA WIRELESS XR80 5G Cellular Router Instructions

SIERRA WIRELESS AirLink LX40 Enterprise LTE Router User Guide