LANCOM 1793VA  
Hardware  
Power supply  
12 V DC, external power adapter (230 V); bayonet connector to secure against disconnec-  
tion  
Gigabit Ethernet 10/100/1000  
TE / NT  
NT  
Power consumption Max. 15 W  
Environment  
Housing  
Temperature range 0–35 °C; humidity 0–95 %, non-condensing  
Robust synthetic housing, rear connectors, ready for wall mounting, Kensington lock;  
dimensions 210 x 45 x 140 mm (W x H x D)  
➁ ➂  
➆➇  
VDSL / ADSL  
ETH 4  
ETH 3  
ETH 2  
ETH 1  
Analog 2/4 Analog 1/3  
Config (Com)  
ISDN 1  
ISDN 2  
USB  
DC 12 V  
Number of fans  
Interfaces  
None; fanless design without rotating parts, high MTBF  
Power  
ISDN 1, 2  
Off  
Green, permanently D-channel active  
Off  
Device switched off  
Interface deactivated  
WAN: VDSL2  
VDSL2 as per ITU G.993.2; profiles 8a, 8b, 8c, 8d, 12a, 12b, 17a, 35b  
VDSL Supervectoring as per ITU G.993.2 (Annex Q)  
VDSL2 vectoring as per ITU G.993.5 (G.Vector)  
Compatible with VDSL2 and U-R2 from Deutsche Telekom (1TR112)  
ADSL2+ over ISDN as per ITU G.992.5 Annex B/J with DPBO, ITU G.992.3, and ITU G.992.1  
ADSL2+ over POTS as per ITU G.992.5 Annex A/M with DPBO, ITU G.992.3, and  
ITU.G.992.1  
Green, permanently* Device operational, resp. device paired  
/ claimed and LANCOM Management  
Cloud (LMC) accessible  
Green, flickering  
Red, flickering  
ISDN data transfer  
ISDN transfer error  
Red / green blinking Configuration password not set.  
Without a configuration password,  
the configuration data in the device is  
unprotected.  
Red / orange, blinking ISDN hardware error  
ETH 1, 2, 3, 4  
Supports just one virtual connection at a time in ATM (VPI-VCI pair)  
Off  
No networking device attached  
VDSL / ADSL interface  
Use the supplied DSL cable for the IP-based line to  
connect the VDSL interface and the provider’s telephone  
socket. For more information, please contact your Internet  
service provider.  
ISDN interfaces  
ISDN 1:  
Internal (NT) or external (TE) ISDN bus.  
This feature is controlled by LCOS.  
ISDN 2:  
ETH  
4 individual ports, 10 / 100 / 1000 Mbps Gigabit Ethernet, by default set to switch mode.  
Up to 3ꢀports can be operated as additional WAN ports. Ethernet ports can be electrically  
disabled in the LCOS configuration.  
Hardware Quick Reference  
Red blinking  
Charge or time limit reached  
Green, permanently Connection to network device  
operational, no data traffic  
1x green inverse  
blinking*  
Connection to the LMC active, pairing  
OK, device not claimed  
USB  
USB 2.0 hi-speed host port for connecting USB printers (USB print server),  
serial devices (COM-port server) or USB drives (FAT file system)  
Green, flickering  
VoIP  
Off  
Data transmission  
2x green inverse  
blinking*  
Pairing error, resp. LMC activation code  
not available  
LANCOM 1793VA  
ISDN 1 / ISDN 2  
ISDN 1: Internal (NT) or external (TE) ISDN bus. This feature is controlled by LCOS. Accor-  
ding to the settings, connect an ISDN cable either to the NTBA or the ISDN terminal device.  
ISDN 2: Internal (NT) ISDN bus. Use an ISDN cable to connect the ISDN device to the ISDN  
interface.  
Internal (NT) ISDN bus.  
3x green inverse  
blinking*  
LMC not accessible,  
resp. communication error  
No SIP accounts defined or VCM is off  
Ethernet interfaces  
Use an Ethernet cable to connect one of the interfaces  
ETH 1 to ETH 4 to your PC or a LAN switch.  
Green, permanently All defined and active SIP accounts  
(outgoing) were successfully  
registered  
A 100-Ohm resistor for line termination is  
switchable in LCOS.  
Online  
Analog 1 / Analog 3 Use the cable of your analog devices to connect them with the analog interfaces. If  
Analog 2 / Analog 4 necessary use the adapters from the LANCOM Analog Adapter Set.  
Off  
WAN connection inactive  
Red, permanently  
Not all defined and active SIP accounts  
were registered (possibly still in  
process)  
Green, blinking  
WAN connection is established (e.g.  
PPP negotiation)  
USB interface  
You can use the USB interface to connect a USB  
printer or a USB memory stick.  
Config (Com) / V.24 Serial configuration interface/COM-port (8-pin mini-DIN): 9,600 - 115,200 baud, suitable  
for optional connection of analog/GPRS modems. Supports internal COM-port server and  
provides transparent asynchronous serial-data transfer via TCP.  
Analog interfaces  
Connect analog terminal devices to the analog interfaces  
either directly via RJ11, or with the help of the enclosed  
TAE adapters.  
Green, permanently WAN connection active  
Red or green,  
inverse flashing  
Number of currently used lines  
(connecting or connected)  
Red, permanently  
DSL  
WAN connection error  
WAN protocols  
Power  
VPN  
Further adapters are optionally available.  
VDSL, ADSL,  
Ethernet  
PPPoE, PPPoA, IPoA, Multi-PPPoE, ML-PPP, PPTP (PAC or PNS) and IPoE (with or without  
DHCP), RIP-1, RIP-2, VLAN  
After connecting the cable to the device, turn the bay-  
onet connector 90° clockwise until it clicks into place.  
Use only the supplied power adapter.  
Off  
Interface deactivated  
Off  
VPN connection inactive  
Green, permanently DSL connection active  
ISDN  
DSS1 (Euro-ISDN), PPP, X75, HDLC, ML-PPP, V.110/GSM/HSCSD  
Configuration interface  
Green, permanently VPN connection active  
Green, flickering  
Red, flickering  
DSL data transfer  
DSL transfer error  
Use a serial configuration cable to connect the serial  
interface (COM) to the serial interface of the device  
you want to use for configuring / monitoring (separately  
available).  
Green, flashing  
VPN connecting  
Package content  
Reset  
Cable  
1 DSL cable for an IP-based line, 4.25 m  
Red / orange, blinking DSL hardware error  
Orange, blinking DSL training  
Orange, permanently DSL sync  
Adapters  
Power adapter  
2 TAE adapters (RJ11 - TAE)  
Reset button  
Operated e.g. with a paper clip  
short press: Restart the device  
long press: Reset the device  
External power supply adapter (230 V), 12 V / 2 A DC/S; barrel / bayonet (EU),  
LANCOM item no. 111303 (not for WW devices)  
Green, blinking  
Analog 1, 2, 3, 4  
Off  
DSL connecting  
Interface deactivated  
Green, permanently Interface activated  
Orange, blinking  
Green, blinking  
Incoming call  
Connection active  
Before initial startup, please make sure to take notice of the information  
regarding the intended use in the enclosed installation guide!  
Please observe the following when setting up the device  
The power plug of the device must be freely accessible.  
i
For devices to be operated on the desktop, please attach the adhesive rubber footpads  
Do not rest any objects on top of the device  
Operate the device only with a professionally installed power supply at a  
nearby power socket that is freely accessible at all times.  
*) The additional power LED statuses are displayed in 5-seconds rotation if the device is configured to be managed by the LANCOM Manage-  
ment Cloud.  
Hereby, LANCOM Systems GmbH | Adenauerstrasse 20/B2 | D-52146 Wuerselen, declares that this device is in compliance  
with Directives 2014/30/EU, 2014/53/EU, 2014/35/EU, 2011/65/EU, and Regulation (EC) No. 1907/2006. The full text of the EU  
Declaration of Conformity is available at the following Internet address: www.lancom-systems.com/doc  
Keep all ventilation slots on the side of the device clear of obstruction  
In case of wall mounting, use the drilling template as supplied  
Rack installation with the optional LANCOM Rack Mount (separately available)  
This product contains separate open-source software components which are subject to their own licenses, in particular the General Public  
License (GPL). The license information for the device firmware (LCOS) is available on the device‘s WEBconfig interface under “Extras > License  
information“. If the respective license demands, the source files for the corresponding software components will be made available on a down-  
load server upon request.  
Cloud-ready  
GeneralDetails
NameLANCOM Systems 1793VA VDSL Voip VPN Router User Guide
MakeLANCOM SYSTEMS
LanguageEnglish
FiletypePDF (Download)
File size0.09 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

If you have any questions regarding LANCOM Systems 1793VA VDSL Voip VPN Router User Guide, please ask here and describe the problem in detail.

Leave a Reply

Your email address will not be published. Required fields are marked *

two + eleven =

LANCOM SYSTEMS 1800EF-4G High Availability Networking Via Fiber Router Owner’s Manual
LANCOM SYSTEMS 1800EF-4G High Availability Networking Via Fiber Router Owner’s Manual
LANCOM SYSTEMS 1930EF Gigabit Ethernet Black Wired Router User Guide
LANCOM SYSTEMS 1930EF Gigabit Ethernet Black Wired Router User Guide
LANCOM SYSTEMS 1790-4G+ High-Performance VPN Router Installation Guide
LANCOM SYSTEMS 1790-4G+ High-Performance VPN Router Installation Guide
LANCOM SYSTEMS 1790VAW GmbH Performance Router User Guide
LANCOM SYSTEMS 1790VAW GmbH Performance Router User Guide
LANCOM SYSTEMS 1800EFW-5G Router Installation Guide
LANCOM SYSTEMS 1800EFW-5G Router Installation Guide
LANCOM Systems 1780EW-4G+ High Performance Mobile VPN Router User Guide
LANCOM Systems 1780EW-4G+ High Performance Mobile VPN Router User Guide
LANCOM SYSTEMS IAP-4G Plus LTE 4G Router User Guide
LANCOM SYSTEMS IAP-4G Plus LTE 4G Router User Guide
LANCOM SYSTEMS LANCOM OAP-830 Wireless Router User Guide
LANCOM SYSTEMS LANCOM OAP-830 Wireless Router User Guide
LANCOM SYSTEMS LANCOM 1790-4G Plus High-Performance VPN Router Instruction Manual
LANCOM SYSTEMS LANCOM 1790-4G Plus High-Performance VPN Router Instruction Manual
LANCOM SYSTEMS VPN 1900EF Router Instruction Manual
LANCOM SYSTEMS VPN 1900EF Router Instruction Manual

LANCOM Systems 1793VA VDSL Voip VPN Router User Guide
Get PDF manual for the LANCOM Systems 1793VA VDSL Voip VPN Router User Guide for free. Access setup steps, installation & Wi-Fi configuration, and troubleshooting tips. 👉 View user guide online or download now!