ufiSpace S9600-72XC Router Installation Guide
enough power is reserved from the power distribution system before installation. Also, please
ensure that both PSUs have been properly installed before powering up the equipment, as the
S9600‐72XC is designed to support 1 + 1 power redundancy.
2. Attach the power cable.
Locate the AC inlet connector on the PSU and plug the AC power cable(250VAC 15A, IEC60320
C15) into the AC inlet connector.
3. Feed AC power into the system.
The PSU will immediately output 12V & 5VSB to the system with a 100‐240V, AC power source.
The PSU has a built‐in 16 amperes, fast acting fuse based on the PSU maximum capacity, which
will act as a second tier system protection in case the power distribution unit’s fuse is not
functioning.
4. Verify that the power supply is operating.
If connected correctly, when turned on, the LED on the PSU will light up with a solid Green
color designating normal operation.
S9600‐72XC Hardware Installation Guide | 21
10 Verifying System Operation
Front Panel LED
Verify basic operations by checking the system LEDs located on the front panel. When operating
normally, the SYS, FAN, PS0 and PS1 LEDs should all display green.
Figure 27.
LED Condition
SYNC
Equipment Status
OFF
System timing synchronization is disabled or in free‐run mode.
System timing core is synchronized to PTP packet(phase) or one of the
external timing sources, frequency is also locked.
Solid Green
System is synchronized with PTP packet (frequency profile) or external
SyncE clock sources.
Blinking Green
Solid Amber
Blinking Amber
SYS
System timing core is in acquiring state or holdover mode.
System timing synchronization fail, or acquiring/holdover time out
OFF
No power
Solid Green
Solid Amber
FAN
Host CPU/BMC boot complete
Power is up but Host CPU/BMC boot failed
OFF
FAN modules are not initialized
Solid Green
Blinking Amber
PS0
All FAN modules are working normal
Fan fail: one or more Fans need service
OFF
No Power
Solid Green
Blinking Amber
PS1
PSU0 is working normal
PSU0 fail (PSU0 need service)
OFF
No Power
Solid Green
Blinking Amber
PSU1 is working normal
PSU 1 fail (PSU1 need service)
S9600‐72XC Hardware Installation Guide | 22
| General | Details |
|---|---|
| Name | ufiSpace S9600-72XC Router Installation Guide |
| Make | UfiSpace |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.84 MB |
If you have any questions regarding ufiSpace S9600-72XC Router Installation Guide, please ask here and describe the problem in detail.

UfiSpace S9500-30XS Gateway Router Installation Guide

UfiSpace S9600-64X 100G Aggregation Router Installation Guide

UfiSpace S9600-32X 100G Aggregation Router Installation Guide

UfiSpace S9501-28SMT Gateway Router Installation Guide