Home > grass valley > Grass Valley MV-825-RTRUM Multiviewer with Integrated Router User Manual

Grass Valley MV-825-RTRUM Multiviewer with Integrated Router User Manual

Maintenance - Hardware  
PSU Module Fitting  
Procedure  
To remove a PSU module:  
1 Identify the PSU module to be removed and disconnect its mains power cord.  
If the MV-825-RTR is powered on, it should continue to operate using the second PSU  
module.  
2 Unscrew two PSU securing screws, see Figure 11-3.  
3 Carefully pull the PSU module out of the MV-825-RTR chassis, using the PSU handle, see  
Figure 11-2.  
PSU Module Fitting  
IMPORTANT:   
Fitting of PSUs should only be attempted by trained personnel.  
A pozidriv screwdriver is required.  
Procedure  
To fit a PSU module:  
1 Note the orientation of a PSU module in the MV-825-RTR chassis, see Figure 11-3.  
2 Carefully insert the PSU module into the empty PSU module slot at the chassis rear.  
When the module is nearly fully pushed in, an increased resistance is met as the  
module’s DC connector engages with the chassis.  
The module should be finally fully pushed in.  
3 Tighten the two PSU securing screws, see Figure 11-3.  
Do not over-tighten the screws.  
4 Connect a power cord and switch the mains supply on.  
The module starts up and the PSU status LED should be lit green.  
The MV-825-RTR operation should be uninterrupted.  
The status LED is described in AC Mains Inlets, on page 25.  
172  
GeneralDetails
NameGrass Valley MV-825-RTRUM Multiviewer with Integrated Router User Manual
Makegrass valley
LanguageEnglish
FiletypePDF (Download)
File size MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

If you have any questions regarding Grass Valley MV-825-RTRUM Multiviewer with Integrated Router User Manual, please ask here and describe the problem in detail.

Leave a Reply

Your email address will not be published. Required fields are marked *

18 − ten =

Grass Valley MV-825-RTRUM Multiviewer with Integrated Router User Manual