Maintenance - Hardware  
Power Supply Units  
Power Supply Units  
WARNING:   
To reduce the risk of electric shock, plug each power supply cord into  
separate branch circuits employing separate service grounds.  
The MV-825-RTR has independent modular dual-redundant power supply units (PSUs).  
Either PSU can supply enough power to the MV-825-RTR chassis. The units are hot-  
swappable.  
Note: To ensure full dual redundancy, the two power supplies must be  
powered from independent power sources.  
Securing Screws  
Air Flow  
IEC Mains Inlet  
Module handle  
Fig. 11-2: MV-825-RTR PSU Module (Grass Valley stock code FGAMV 820-PSU)  
Two PSU modules are fitted into the rear of the MV-825-RTR chassis. Each is secured with  
two fixing screws, see Figure 11-3.  
Each PSU has an IEC mains inlet and a status LED. The PSU status LEDs are described in AC  
Mains Inlets, on page 25.  
170  
GeneralDetails