3.2 Power source requirement  
This device may only be operated with power supplies that meet the requirements of EN 62368-1 for  
power sources of limited power. Otherwise, the device must be operated in a housing that meets the re-  
quirements of fire protection according to EN 62368-1.  
3.3 Terminals and Interfaces  
Rigid copper wires with a max. diameter of 1.5 mm² can be clamped onto the provided connector plug.  
Network cables corresponding to at least category 5/5e (CAT-5) should be connected to the RJ-45 sockets.  
3.4 Installation position/minimum clearances  
The router was designed to be mounted on DIN rails (as per DIN EN 50 022) and intended for installation  
in switch cabinets. Installation and mounting must take place in accordance with VDE 0100/IEC 364.  
The router can be installed in any position.  
It is recommended that minimum clearances to neighboring assemblies are observed during assembly. If  
the distances 30 mm on the top and on bottom and 10 mm on each side are maintained, easy access to  
the connections and contact options on the router is possible without having to remove other system  
parts. In addition, there should always be enough space for the necessary cable routing.  
3.5 Digital inputs/outputs IO1 and IO2  
The bidirectional connections IO 1 and IO2 can - independently of one another be configured as digital  
inputs (standard setting) or as digital outputs.  
3.5.1 Inputs  
The alarm inputs can be activated  
with potential-free switches, buttons  
or relay contacts. IN1 can, for exam-  
ple, be used for the VPN establishing  
of connection with the myREX24  
portal. An alarm can be triggered  
with the IN2.  
Example wiring of the inputs:  
3.5.2 Outputs  
When selecting for the output circuit,  
the REX can provide the status of an  
active Internet, VPN or user portal  
connection as a signal. Each output  
can have a max. 0.5A (@ 24 V).  
Example wiring of the outputs:  
QuickStart Guide REX 100 | Version 14 | 22.01.2025  
7
           
GeneralDetails
NameHelmholz 700-875-LTE11, 700-875-LTE61 REX 100 Router User Guide
MakeHelmholz
LanguageEnglish
FiletypePDF (Download)
File size MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

If you have any questions regarding Helmholz 700-875-LTE11, 700-875-LTE61 REX 100 Router User Guide, please ask here and describe the problem in detail.

Leave a Reply

Your email address will not be published. Required fields are marked *

five × 1 =

Helmholz 700-875-WIF51 REX 100 Router User Guide
Helmholz 700-875-WIF51 REX 100 Router User Guide
Helmholz LTE11 Router Owner’s Manual
Helmholz LTE11 Router Owner’s Manual

Helmholz 700-875-LTE11, 700-875-LTE61 REX 100 Router User Guide