INTRODUCTION
This document guides users through checkout and commissioning of an Airflow
Measurement System (AFMS). It is designed to aid in completing the tasks on
the Note Sheets for AFMS Checkout and Commissioning.
The BAC-5051(A)E router can be used to configure, control, tune, and monitor
the operation of an AFMS. AFMS features are accessible through the Balancing
/ AFMS / ZEC web page and are active once a valid AFMS controller has been
discovered.
NOTE: The default IP address of the BAC-5051(A)E router is 192.168.1.252.
PREREQUISITES
1. Install the AFMS (the controller and all system components).
NOTE: See the AFMS installation guide found on any AFMS controller’s product
page.
2. Select the application (on the AFMS controller) needed for the equipment.
NOTE: See the AFMS selection guide for a table listing the configuration tools
that can be used to select the application. Select the application before
configuring other settings. Changing applications after configuration
will restore most parameters to their defaults.
3. Set the AFMS controller’s communication parameters.
NOTE: See the AFMS selection guide for a table listing the configuration tools
that can be used to set the communication parameters.
4. Configure the router and set up routing to the AFMS controller.
NOTE: See the Application and Installation Guide for the BAC-5051AE Router
for details.
ACCESSING THE AFMS PAGES
1. Log in to the router using a web browser.
NOTE: See the Application and Installation Guide for the BAC-5051AE Router
for details.
2. Go to Advanced > Balancing / AFMS / ZEC.
3. For Instance Range, in Start, enter the device instance that was set for the
AFMS controller.
NOTE: End automatically fills with a value, making a range of 50 device
instances.
4. Click Discover.
5. Click the circle next to the AFMS controller’s Instance.
NOTE: The selected AFMS controller highlights and the AFMS configuration
page tabs appear below.
2
BAC-5051(A)E Pages for Configuring an AFMS, AG230819C
| General | Details |
|---|---|
| Name | KMC Controls BAC-5051 TRUEFIT Measurement System Router User Guide |
| Make | KMC CONTROLS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.27 MB |
If you have any questions regarding KMC Controls BAC-5051 TRUEFIT Measurement System Router User Guide, please ask here and describe the problem in detail.

KMC CONTROLS Conquest BAC-5051AE BACnet Router Instruction Manual

KMC CONTROLS BAC-5051AE BACnet Router Owner’s Manual