User=Phone: “User=Phone” parameter will be attached to the Request-Line and “From” header in the SIP request to  
indicate the E.164 number. If set to “Enable”.  
Please consult your carrier before changing this parameter. Default is Disabled.  
Use Request  
Routing ID in  
SIP INVITE  
Header  
If set to Yes, device will use the configured [Request URI Routing ID] in the SIP INVITE. This option is usually used  
under a SIP trunk account’s configuration. Default is No.  
SIP Registration  
Controls whether the HT81x needs to send REGISTER messages to the proxy server. Default setting is Yes.  
Controls whether to clear SIP user’s information by sending un-register request to the proxy server. The un-  
registration is performed by sending a REGISTER message with “Expires=0” parameter to the SIP server. This will  
unregister the SIP account under the concerned FXS page.Unregister on reboot option can be set to "No", "All" or  
"Instance".  
1. Set to "No": If the "Unregister on reboot" option is set to "No", it means that the SIP user's information will not  
be cleared when the device reboots. In other words, the SIP account will remain registered with the server even  
after the device is rebooted.  
Unregister on  
Reboot  
2. Set to "All": If the "Unregister on reboot" option is set to "All", it means that all SIP accounts associated with the  
device will be unregistered when the device reboots. This option clears the SIP user's information for all the FXS  
ports on the device.  
3. Set to "Instance": If the "Unregister on reboot" option is set to "Instance", it means that only the SIP account  
associated with the concerned FXS port will be unregistered when the device reboots. This option clears the SIP  
user's information for only the specific FXS port that is affected by the reboot.  
Default value is set to "No"  
Outgoing Call  
Without  
Enables the ability to place outgoing calls even if the account is not registered (if allowed by ITSP); device will not be  
able to receive incoming calls. Default is No.  
Registration  
Refreshes registration periodically with specified SIP proxy (in minutes). Maximum interval is 65535 minutes (about  
Register  
45 days).  
Expiration  
Default is 60 minutes (or 1 hour).  
Reregister  
Before  
Sends re-register request after specific time (in seconds) to renew registration before the previous registration expires.  
Expiration  
Sends re-register request after specific time (in seconds) when registration process fails. Maximum interval is 3600  
SIP Registration  
Failure Retry  
Wait Time  
seconds (1 hour).  
Default is 20 seconds.  
SIP Registration  
Failure Retry  
Sends re-register request after specific time (in seconds) when registration process fails with error 403 Forbidden.  
Maximum interval is 3600 seconds (1 hour). Default is 1200 seconds.  
Wait Time upon  
403 Forbidden  
Port Voltage Off  
upon no SIP  
Registration or  
SIP Registration  
Failure  
Allows users to configure the timer of Port Voltage Off.  
For Port Voltage Off upon no SIP, the Valid Range is 0 to 60 with the Default value being 0 ( 0 means the port voltage  
is never turned off )  
Delay Time of  
Port Voltage Off  
Timer Since  
Boot  
Enables SIP OPTIONS or SIP NOTIFY to track account registration status so the ATA will send periodic  
OPTIONS/NOTIFY message to server to track the connection status with the server.  
Default setting is No.  
Enable SIP  
OPTIONS/NOTI  
FY Keep Alive  
SIP  
Configures the time interval when the ATA send OPTIONS or NOTIFY message to SIP server. The default setting is  
30 seconds, which means the ATA will send an OPTIONS/NOTIFY message to the server every 30 seconds. The  
default range is 1-64800.  
OPTIONS/NOTI  
FY Keep Alive  
Interval  
SIP OPTIONS  
Keep Alive Max  
Lost  
Defines the Number of max lost packets for SIP OPTIONS Keep Alive before re-registration. Between 3-10, default  
is 3.  
Defines Diff-Serv values for SIP and RTP.  
Layer 3 QoS  
SIP DSCP (Diff-Serv value in decimal, 0-63, default 26)  
RTP DSCP (Diff-Serv value in decimal, 0-63, default 46)  
Defines local port to use by the HT81x for listening and transmitting SIP packets. Default value for FXS 1 is 5060 and  
5062 for FXS 2.  
Local SIP Port  
Local RTP Port  
Defines the local RTP-RTCP port pair the HT81x will listen and transmit. It is the HT81x RTP port for channel 0.  
The default value for FXS port is 5004  
Controls whether to use configured or random SIP ports. This is usually necessary when multiple HT81x are behind  
the same NAT.  
Use Random SIP  
Port  
Default is No.  
Controls whether to use configured or random RTP ports. This is usually necessary when multiple HT81x are behind  
Use Random  
RTP Port  
the same NAT.  
Default is No.  
GeneralDetails
NameGRANDSTREAM HT812 Analog FXS IP Gateway 2 Port + NAT Router User Guide
MakeGRANDSTREAM
LanguageEnglish
FiletypePDF (Download)
File size MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

If you have any questions regarding GRANDSTREAM HT812 Analog FXS IP Gateway 2 Port + NAT Router User Guide, please ask here and describe the problem in detail.

Leave a Reply

Your email address will not be published. Required fields are marked *

thirteen − 12 =

GRANDSTREAM GWN7062E Wi-Fi 6 Router Instruction Manual
GRANDSTREAM GWN7062E Wi-Fi 6 Router Instruction Manual
GRANDSTREAM GWN7052F Dual Band Wi-Fi Router Installation Guide
GRANDSTREAM GWN7052F Dual Band Wi-Fi Router Installation Guide
GRANDSTREAM GWN7062 Dual-band WiFi 6 Router Installation Guide
GRANDSTREAM GWN7062 Dual-band WiFi 6 Router Installation Guide
GRANDSTREAM HT812 Powerful 2 Port ATA with Gigabit NAT Router User Guide
GRANDSTREAM HT812 Powerful 2 Port ATA with Gigabit NAT Router User Guide
GRANDSTREAM GWN700x VPN Router User Guide
GRANDSTREAM GWN700x VPN Router User Guide

GRANDSTREAM HT812 Analog FXS IP Gateway 2 Port + NAT Router User Guide